On this page
dellemc.openmanage.dellemc_configure_idrac_eventing – Configures the iDRAC eventing related attributes
Note
This plugin is part of the dellemc.openmanage collection (version 3.0.0).
To install it use: ansible-galaxy collection install dellemc.openmanage
.
To use it in a playbook, specify: dellemc.openmanage.dellemc_configure_idrac_eventing
.
New in version 1.0.0: of dellemc.openmanage
Synopsis
- This module allows to configure the iDRAC eventing related attributes.
Requirements
The below requirements are needed on the host that executes this module.
- omsdk
- python >= 2.7.5
Parameters
Parameter | Choices/Defaults | Comments |
---|---|---|
address
string
|
Email address for SNMP Trap.
|
|
alert_number
integer
|
Alert number for Email configuration.
|
|
authentication
string
|
|
Simple Mail Transfer Protocol Authentication.
|
custom_message
string
|
Custom message for SNMP Trap reference.
|
|
destination
string
|
Destination for SNMP Trap.
|
|
destination_number
integer
|
Destination number for SNMP Trap.
|
|
email_alert_state
string
|
|
Whether to Enable or Disable Email alert.
|
enable_alerts
string
|
|
Whether to Enable or Disable iDRAC alerts.
|
idrac_ip
string / required
|
iDRAC IP Address.
|
|
idrac_password
string / required
|
iDRAC user password.
aliases: idrac_pwd |
|
idrac_port
integer
|
Default:
443
|
iDRAC port.
|
idrac_user
string / required
|
iDRAC username.
|
|
password
string
|
Password for SMTP authentication.
|
|
share_mnt
string
|
Local mount path of the network share with read-write permission for ansible user. This option is mandatory for Network Share.
|
|
share_name
string / required
|
Network share or a local path.
|
|
share_password
string
|
Network share user password. This option is mandatory for CIFS Network Share.
aliases: share_pwd |
|
share_user
string
|
Network share user in the format 'user@domain' or 'domain\user' if user is part of a domain else 'user'. This option is mandatory for CIFS Network Share.
|
|
smtp_ip_address
string
|
SMTP IP address for communication.
|
|
smtp_port
string
|
SMTP Port number for access.
|
|
snmp_trap_state
string
|
|
Whether to Enable or Disable SNMP alert.
|
snmp_v3_username
string
|
SNMP v3 username for SNMP Trap.
|
|
username
string
|
Username for SMTP authentication.
|
Notes
Note
- Run this module from a system that has direct access to DellEMC iDRAC.
- This module supports
check_mode
.
Examples
---
- name: Configure the iDRAC eventing attributes
dellemc.openmanage.dellemc_configure_idrac_eventing:
idrac_ip: "192.168.0.1"
idrac_user: "user_name"
idrac_password: "user_password"
share_name: "192.168.0.1:/share"
share_password: "share_user"
share_user: "share_password"
share_mnt: "/mnt/share"
destination_number: "2"
destination: "1.1.1.1"
snmp_v3_username: "None"
snmp_trap_state: "Enabled"
email_alert_state: "Disabled"
alert_number: "1"
address: "alert_email@company.com"
custom_message: "Custom Message"
enable_alerts: "Disabled"
authentication: "Enabled"
smtp_ip_address: "192.168.0.1"
smtp_port: "25"
username: "username"
password: "password"
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
error_info
dictionary
|
on HTTP error |
Details of the HTTP Error.
Sample:
{'error': {'@Message.ExtendedInfo': [{'Message': 'Unable to process the request because an error occurred.', 'MessageArgs': [], 'MessageId': 'GEN1234', 'RelatedProperties': [], 'Resolution': 'Retry the operation. If the issue persists, contact your system administrator.', 'Severity': 'Critical'}], 'code': 'Base.1.0.GeneralError', 'message': 'A general error has occurred. See ExtendedInfo for more information.'}}
|
eventing_status
dictionary
|
success |
Configures the iDRAC eventing attributes.
Sample:
{'CompletionTime': '2020-04-02T02:43:28', 'Description': 'Job Instance', 'EndTime': None, 'Id': 'JID_12345123456', 'JobState': 'Completed', 'JobType': 'ImportConfiguration', 'Message': 'Successfully imported and applied Server Configuration Profile.', 'MessageArgs': [], 'MessageId': 'SYS053', 'Name': 'Import Configuration', 'PercentComplete': 100, 'StartTime': 'TIME_NOW', 'Status': 'Success', 'TargetSettingsURI': None, 'retval': True}
|
msg
string
|
always |
Successfully configured the iDRAC eventing settings.
Sample:
Successfully configured the iDRAC eventing settings.
|
Authors
- Felix Stephen (@felixs88)