On this page
bigip_gtm_monitor_https – Manages F5 BIG-IP GTM https monitors
New in version 2.6.
Synopsis
- Manages F5 BIG-IP GTM https monitors.
 
Parameters
| Parameter | Choices/Defaults | Comments | |
|---|---|---|---|
| cipher_list
        
        string
         | 
      
        
        Specifies the list of ciphers for this monitor.
        
       
        The items in the cipher list are separated with the colon  
       : symbol.
       
        When creating a new monitor, if this parameter is not specified, the default list is  DEFAULT:+SHA:+3DES:+kEDH.
        | 
     ||
| client_cert
        
        string
         | 
      
        
        Specifies a fully-qualified path for a client certificate that the monitor sends to the target SSL server.
         | 
     ||
| client_key
        
        string
         | 
      
        
        Specifies a key for a client certificate that the monitor sends to the target SSL server.
         | 
     ||
| compatibility
        
        boolean
         | 
      
       
  | 
      
        
        Specifies, when enabled, that the SSL options setting (in OpenSSL) is set to all.
        
       
        When creating a new monitor, if this value is not specified, the default is  yes
        | 
     |
| ignore_down_response
        
        boolean
         | 
      
       
  | 
      
        
        Specifies that the monitor allows more than one probe attempt per interval.
        
       
        When  
       yes, specifies that the monitor ignores down responses for the duration of the monitor timeout. Once the monitor timeout is reached without the system receiving an up response, the system marks the object down.
       
        When  
       no, specifies that the monitor immediately marks an object down when it receives a down response.
       
        When creating a new monitor, if this parameter is not provided, then the default value will be  no.
        | 
     |
| interval
        
        integer
         | 
      
        
        The interval specifying how frequently the monitor instance of this template will run.
        
       
        If this parameter is not provided when creating a new monitor, then the default value will be 30.
        
       
        This value must be less than the  timeout value.
        | 
     ||
| ip
        
        string
         | 
      
        
        IP address part of the IP/port definition. If this parameter is not provided when creating a new monitor, then the default value will be '*'.
        
       
        If this value is an IP address, then a  port number must be specified.
        | 
     ||
| name
        
        string / required
         | 
      
        
        Monitor name.
         | 
     ||
| parent
        
        string
         | 
      Default: 
        "/Common/https"
         | 
      
        
        The parent template of this monitor template. Once this value has been set, it cannot be changed. By default, this value is the  tcp parent on the Common partition.
        | 
     |
| partition
        
        string
         | 
      Default: 
        "Common"
         | 
      
        
        Device partition to manage resources on.
         | 
     |
| password
        
        string / required
         | 
      
        
        The password for the user account used to connect to the BIG-IP.
        
       
        You may omit this option by setting the environment variable  
       F5_PASSWORD.
       aliases: pass, pwd  | 
     ||
| port
        
        string
         | 
      
        
        Port address part of the IP/port definition. If this parameter is not provided when creating a new monitor, then the default value will be '*'. Note that if specifying an IP address, a value between 1 and 65535 must be specified.
         | 
     ||
| probe_timeout
        
        integer
         | 
      
        
        Specifies the number of seconds after which the system times out the probe request to the system.
        
       
        When creating a new monitor, if this parameter is not provided, then the default value will be  5.
        | 
     ||
| provider
        
        dictionary
        
       
        added in 2.5
         | 
      
        
        A dict object containing connection details.
         | 
     ||
| password
        
        string / required
         | 
      
        
        The password for the user account used to connect to the BIG-IP.
        
       
        You may omit this option by setting the environment variable  
       F5_PASSWORD.
       aliases: pass, pwd  | 
     ||
| server
        
        string / required
         | 
      
        
        The BIG-IP host.
        
       
        You may omit this option by setting the environment variable  F5_SERVER.
        | 
     ||
| server_port
        
        integer
         | 
      Default: 
        443
         | 
      
        
        The BIG-IP server port.
        
       
        You may omit this option by setting the environment variable  F5_SERVER_PORT.
        | 
     |
| ssh_keyfile
        
        path
         | 
      
        
        Specifies the SSH keyfile to use to authenticate the connection to the remote device. This argument is only used for cli transports.
        
       
        You may omit this option by setting the environment variable  ANSIBLE_NET_SSH_KEYFILE.
        | 
     ||
| timeout
        
        integer
         | 
      Default: 
        10
         | 
      
        
        Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error.
         | 
     |
| transport
        
        string
         | 
      
       
  | 
      
        
        Configures the transport connection to use when connecting to the remote device.
         | 
     |
| user
        
        string / required
         | 
      
        
        The username to connect to the BIG-IP with. This user must have administrative privileges on the device.
        
       
        You may omit this option by setting the environment variable  F5_USER.
        | 
     ||
| validate_certs
        
        boolean
         | 
      
       
  | 
      
        
        If  
       no, SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.
       
        You may omit this option by setting the environment variable  F5_VALIDATE_CERTS.
        | 
     |
| receive
        
        string
         | 
      
        
        The receive string for the monitor call.
         | 
     ||
| reverse
        
        boolean
         | 
      
       
  | 
      
        
        Instructs the system to mark the target resource down when the test is successful. This setting is useful, for example, if the content on your web site home page is dynamic and changes frequently, you may want to set up a reverse ECV service check that looks for the string Error.
        
       
        A match for this string means that the web server was down.
        
       
        To use this option, you must specify values for  send and receive.
        | 
     |
| send
        
        string
         | 
      
        
        The send string for the monitor call.
        
       
        When creating a new monitor, if this parameter is not provided, the default of  GET /\r\n will be used.
        | 
     ||
| server
        
        string / required
         | 
      
        
        The BIG-IP host.
        
       
        You may omit this option by setting the environment variable  F5_SERVER.
        | 
     ||
| server_port
        
        integer
        
       
        added in 2.2
         | 
      Default: 
        443
         | 
      
        
        The BIG-IP server port.
        
       
        You may omit this option by setting the environment variable  F5_SERVER_PORT.
        | 
     |
| state
        
        string
         | 
      
       
  | 
      
        
        When  
       present, ensures that the monitor exists.
       
        When  absent, ensures the monitor is removed.
        | 
     |
| target_password
        
        string
         | 
      
        
        Specifies the password, if the monitored target requires authentication.
         | 
     ||
| target_username
        
        string
         | 
      
        
        Specifies the user name, if the monitored target requires authentication.
         | 
     ||
| timeout
        
        integer
         | 
      
        
        The number of seconds in which the node or service must respond to the monitor request. If the target responds within the set time period, it is considered up. If the target does not respond within the set time period, it is considered down. You can change this number to any number you want, however, it should be 3 times the interval number of seconds plus 1 second.
        
       
        If this parameter is not provided when creating a new monitor, then the default value will be 120.
         | 
     ||
| transparent
        
        boolean
         | 
      
       
  | 
      
        
        Specifies whether the monitor operates in transparent mode.
        
       
        A monitor in transparent mode directs traffic through the associated pool members or nodes (usually a router or firewall) to the aliased destination (that is, it probes the  
       ip-port combination specified in the monitor).
       
        If the monitor cannot successfully reach the aliased destination, the pool member or node through which the monitor traffic was sent is marked down.
        
       
        When creating a new monitor, if this parameter is not provided, then the default value will be  no.
        | 
     |
| update_password
        
        string
         | 
      
       
  | 
      
       always will update passwords if the target_password is specified.
       on_create will only set the password for newly created monitors.
        | 
     |
| user
        
        string / required
         | 
      
        
        The username to connect to the BIG-IP with. This user must have administrative privileges on the device.
        
       
        You may omit this option by setting the environment variable  F5_USER.
        | 
     ||
| validate_certs
        
        boolean
        
       
        added in 2.0
         | 
      
       
  | 
      
        
        If  
       no, SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.
       
        You may omit this option by setting the environment variable  F5_VALIDATE_CERTS.
        | 
     |
Notes
Note
- For more information on using Ansible to manage F5 Networks devices see https://www.ansible.com/integrations/networks/f5.
 - Requires BIG-IP software version >= 12.
 - The F5 modules only manipulate the running configuration of the F5 product. To ensure that BIG-IP specific configuration persists to disk, be sure to include at least one task that uses the bigip_config module to save the running configuration. Refer to the module’s documentation for the correct usage of the module to save your running configuration.
 
Examples
- name: Create a GTM HTTPS monitor
  bigip_gtm_monitor_https:
    name: my_monitor
    ip: 1.1.1.1
    port: 80
    send: my send string
    receive: my receive string
    state: present
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost
- name: Remove HTTPS Monitor
  bigip_gtm_monitor_https:
    name: my_monitor
    state: absent
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost
- name: Add HTTPS monitor for all addresses, port 514
  bigip_gtm_monitor_https:
    name: my_monitor
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
    port: 514
  delegate_to: localhost
  Return Values
Common return values are documented here, the following are the fields unique to this module:
| Key | Returned | Description | 
|---|---|---|
| cipher_list
        
        string
         | 
      changed | 
        
        The new value for the cipher list.
         Sample:
        
       
        +3DES:+kEDH
         | 
     
| client_cert
        
        string
         | 
      changed | 
        
        The new client cert setting.
         Sample:
        
       
        /Common/default
         | 
     
| client_key
        
        string
         | 
      changed | 
        
        The new client key setting.
         Sample:
        
       
        /Common/default
         | 
     
| compatibility
        
        boolean
         | 
      changed | 
        
        The new SSL compatibility setting.
         Sample:
        
       
        True
         | 
     
| ignore_down_response
        
        boolean
         | 
      changed | 
        
        Whether to ignore the down response or not.
         Sample:
        
       
        True
         | 
     
| interval
        
        integer
         | 
      changed | 
        
        The new interval in which to run the monitor check.
         Sample:
        
       
        2
         | 
     
| ip
        
        string
         | 
      changed | 
        
        The new IP of IP/port definition.
         Sample:
        
       
        10.12.13.14
         | 
     
| parent
        
        string
         | 
      changed | 
        
        New parent template of the monitor.
         Sample:
        
       
        https
         | 
     
| port
        
        string
         | 
      changed | 
        
        The new port the monitor checks the resource on.
         Sample:
        
       
        8080
         | 
     
| probe_timeout
        
        integer
         | 
      changed | 
        
        The new timeout in which the system will timeout the monitor probe.
         Sample:
        
       
        10
         | 
     
| receive
        
        string
         | 
      changed | 
        
        The new receive string for this monitor.
         Sample:
        
       
        tcp string to receive
         | 
     
| reverse
        
        boolean
         | 
      changed | 
        
        The new value for whether the monitor operates in reverse mode.
          | 
     
| send
        
        string
         | 
      changed | 
        
        The new send string for this monitor.
         Sample:
        
       
        tcp string to send
         | 
     
| timeout
        
        integer
         | 
      changed | 
        
        The new timeout in which the remote system must respond to the monitor.
         Sample:
        
       
        10
         | 
     
| transparent
        
        boolean
         | 
      changed | 
        
        The new value for whether the monitor operates in transparent mode.
          | 
     
Status
- This module is not guaranteed to have a backwards compatible interface. [preview]
 - This module is maintained by an Ansible Partner. [certified]
 
Authors
- Tim Rupp (@caphrim007)
 - Wojciech Wypior (@wojtek0806)
 
Hint
If you notice any issues in this documentation you can edit this document to improve it.
© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
 https://docs.ansible.com/ansible/2.8/modules/bigip_gtm_monitor_https_module.html