On this page
aci_domain – Manage physical, virtual, bridged, routed or FC domain profiles (phys:DomP, vmm:DomP, l2ext:DomP, l3ext:DomP, fc:DomP)
New in version 2.5.
Synopsis
- Manage physical, virtual, bridged, routed or FC domain profiles on Cisco ACI fabrics.
Parameters
| Parameter | Choices/Defaults | Comments |
|---|---|---|
| certificate_name
string
|
The X.509 certificate name attached to the APIC AAA user used for signature-based authentication.
If a
private_key filename was provided, this defaults to the private_key basename, without extension.
If PEM-formatted content was provided for
private_key, this defaults to the username value.
aliases: cert_name |
|
| domain
string
|
Name of the physical, virtual, bridged routed or FC domain profile.
aliases: domain_name, domain_profile, name |
|
| domain_type
string
|
|
The type of domain profile.
fc: The FC domain profile is a policy pertaining to single FC Management domain
l2dom: The external bridged domain profile is a policy for managing L2 bridged infrastructure bridged outside the fabric.
l3dom: The external routed domain profile is a policy for managing L3 routed infrastructure outside the fabric.
phys: The physical domain profile stores the physical resources and encap resources that should be used for EPGs associated with this domain.
vmm: The VMM domain profile is a policy for grouping VM controllers with similar networking policy requirements.
aliases: type |
| dscp
string
|
|
The target Differentiated Service (DSCP) value.
The APIC defaults to
unspecified when unset during creation.
aliases: target |
| encap_mode
string
|
|
The layer 2 encapsulation protocol to use with the virtual switch.
|
| host
string / required
|
IP Address or hostname of APIC resolvable by Ansible control host.
aliases: hostname |
|
| multicast_address
string
|
The multicast IP address to use for the virtual switch.
|
|
| output_level
string
|
|
Influence the output of this ACI module.
normal means the standard output, incl. current dict
info adds informational output, incl. previous, proposed and sent dicts
debug adds debugging output, incl. filter_string, method, response, status and url information
|
| password
string / required
|
The password to use for authentication.
This option is mutual exclusive with private_key. If private_key is provided too, it will be used instead.
|
|
| port
integer
|
Port number to be used for REST connection.
The default value depends on parameter use_ssl.
|
|
| private_key
string / required
|
Either a PEM-formatted private key file or the private key content used for signature-based authentication.
This value also influences the default
certificate_name that is used.
This option is mutual exclusive with
password. If password is provided too, it will be ignored.
aliases: cert_key |
|
| state
string
|
|
Use
present or absent for adding or removing.
Use query for listing an object or multiple objects.
|
| timeout
integer
|
Default:
30
|
The socket level timeout in seconds.
|
| use_proxy
boolean
|
|
If no, it will not use a proxy, even if one is defined in an environment variable on the target hosts.
|
| use_ssl
boolean
|
|
If no, an HTTP connection will be used instead of the default HTTPS connection.
|
| username
string
|
Default:
"admin"
|
The username to use for authentication.
aliases: user |
| validate_certs
boolean
|
|
If
no, SSL certificates will not be validated.
This should only set to no when used on personally controlled sites using self-signed certificates.
|
| vm_provider
string
|
|
The VM platform for VMM Domains.
Support for Kubernetes was added in ACI v3.0.
Support for CloudFoundry, OpenShift and Red Hat was added in ACI v3.1.
|
| vswitch
string
|
|
The virtual switch to use for vmm domains.
The APIC defaults to default when unset during creation.
|
See Also
See also
- aci_aep_to_domain – Bind AEPs to Physical or Virtual Domains (infra:RsDomP)
- The official documentation on the aci_aep_to_domain module.
- aci_domain_to_encap_pool – Bind Domain to Encap Pools (infra:RsVlanNs)
- The official documentation on the aci_domain_to_encap_pool module.
- aci_domain_to_vlan_pool – Bind Domain to VLAN Pools (infra:RsVlanNs)
- The official documentation on the aci_domain_to_vlan_pool module.
- APIC Management Information Model reference
- More information about the internal APIC classes phys:DomP, vmm:DomP, l2ext:DomP, l3ext:DomP and fc:DomP
- Cisco ACI Guide
- Detailed information on how to manage your ACI infrastructure using Ansible.
- Developing Cisco ACI modules
- Detailed guide on how to write your own Cisco ACI modules to contribute.
Examples
- name: Add a new physical domain
aci_domain:
host: apic
username: admin
password: SomeSecretPassword
domain: phys_dom
domain_type: phys
state: present
- name: Remove a physical domain
aci_domain:
host: apic
username: admin
password: SomeSecretPassword
domain: phys_dom
domain_type: phys
state: absent
- name: Add a new VMM domain
aci_domain:
host: apic
username: admin
password: SomeSecretPassword
domain: hyperv_dom
domain_type: vmm
vm_provider: microsoft
state: present
delegate_to: localhost
- name: Remove a VMM domain
aci_domain:
host: apic
username: admin
password: SomeSecretPassword
domain: hyperv_dom
domain_type: vmm
vm_provider: microsoft
state: absent
delegate_to: localhost
- name: Query a specific physical domain
aci_domain:
host: apic
username: admin
password: SomeSecretPassword
domain: phys_dom
domain_type: phys
state: query
delegate_to: localhost
register: query_result
- name: Query all domains
aci_domain:
host: apic
username: admin
password: SomeSecretPassword
domain_type: phys
state: query
delegate_to: localhost
register: query_result
Return Values
Common return values are documented here, the following are the fields unique to this module:
| Key | Returned | Description |
|---|---|---|
| current
list
|
success |
The existing configuration from the APIC after the module has finished
Sample:
[{'fvTenant': {'attributes': {'descr': 'Production environment', 'dn': 'uni/tn-production', 'name': 'production', 'nameAlias': '', 'ownerKey': '', 'ownerTag': ''}}}]
|
| error
dictionary
|
failure |
The error information as returned from the APIC
Sample:
{'code': '122', 'text': 'unknown managed object class foo'}
|
| filter_string
string
|
failure or debug |
The filter string used for the request
Sample:
?rsp-prop-include=config-only
|
| method
string
|
failure or debug |
The HTTP method used for the request to the APIC
Sample:
POST
|
| previous
list
|
info |
The original configuration from the APIC before the module has started
Sample:
[{'fvTenant': {'attributes': {'descr': 'Production', 'dn': 'uni/tn-production', 'name': 'production', 'nameAlias': '', 'ownerKey': '', 'ownerTag': ''}}}]
|
| proposed
dictionary
|
info |
The assembled configuration from the user-provided parameters
Sample:
{'fvTenant': {'attributes': {'descr': 'Production environment', 'name': 'production'}}}
|
| raw
string
|
parse error |
The raw output returned by the APIC REST API (xml or json)
Sample:
<?xml version="1.0" encoding="UTF-8"?><imdata totalCount="1"><error code="122" text="unknown managed object class foo"/></imdata>
|
| response
string
|
failure or debug |
The HTTP response from the APIC
Sample:
OK (30 bytes)
|
| sent
list
|
info |
The actual/minimal configuration pushed to the APIC
Sample:
{'fvTenant': {'attributes': {'descr': 'Production environment'}}}
|
| status
integer
|
failure or debug |
The HTTP status from the APIC
Sample:
200
|
| url
string
|
failure or debug |
The HTTP url used for the request to the APIC
Sample:
https://10.11.12.13/api/mo/uni/tn-production.json
|
Status
- This module is not guaranteed to have a backwards compatible interface. [preview]
- This module is maintained by an Ansible Partner. [certified]
Authors
- Dag Wieers (@dagwieers)
Hint
If you notice any issues in this documentation, you can edit this document to improve it.
© 2012–2018 Michael DeHaan
© 2018–2019 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.9/modules/aci_domain_module.html