On this page
dellemc.openmanage.dellemc_configure_idrac_eventing – Configures the iDRAC eventing related attributes
Note
This plugin is part of the dellemc.openmanage collection (version 3.6.0).
You might already have this collection installed if you are using the ansible
package. It is not included in ansible-core
. To check whether it is installed, run ansible-galaxy collection list
.
To install it, use: ansible-galaxy collection install dellemc.openmanage
.
To use it in a playbook, specify: dellemc.openmanage.dellemc_configure_idrac_eventing
.
New in version 1.0.0: of dellemc.openmanage
Synopsis
- This module allows to configure the iDRAC eventing related attributes.
Requirements
The below requirements are needed on the host that executes this module.
- omsdk
- python >= 2.7.5
Parameters
Parameter | Choices/Defaults | Comments |
---|---|---|
address
string
|
Email address for SNMP Trap.
|
|
alert_number
integer
|
Alert number for Email configuration.
|
|
authentication
string
|
|
Simple Mail Transfer Protocol Authentication.
|
custom_message
string
|
Custom message for SNMP Trap reference.
|
|
destination
string
|
Destination for SNMP Trap.
|
|
destination_number
integer
|
Destination number for SNMP Trap.
|
|
email_alert_state
string
|
|
Whether to Enable or Disable Email alert.
|
enable_alerts
string
|
|
Whether to Enable or Disable iDRAC alerts.
|
idrac_ip
string / required
|
iDRAC IP Address.
|
|
idrac_password
string / required
|
iDRAC user password.
aliases: idrac_pwd |
|
idrac_port
integer
|
Default:
443
|
iDRAC port.
|
idrac_user
string / required
|
iDRAC username.
|
|
password
string
|
Password for SMTP authentication.
|
|
share_mnt
string
|
Local mount path of the network share with read-write permission for ansible user. This option is mandatory for Network Share.
|
|
share_name
string / required
|
Network share or a local path.
|
|
share_password
string
|
Network share user password. This option is mandatory for CIFS Network Share.
aliases: share_pwd |
|
share_user
string
|
Network share user in the format 'user@domain' or 'domain\user' if user is part of a domain else 'user'. This option is mandatory for CIFS Network Share.
|
|
smtp_ip_address
string
|
SMTP IP address for communication.
|
|
smtp_port
string
|
SMTP Port number for access.
|
|
snmp_trap_state
string
|
|
Whether to Enable or Disable SNMP alert.
|
snmp_v3_username
string
|
SNMP v3 username for SNMP Trap.
|
|
username
string
|
Username for SMTP authentication.
|
Notes
Note
- This module requires ‘Administrator’ privilege for idrac_user.
- Run this module from a system that has direct access to Dell EMC iDRAC.
- This module supports
check_mode
.
Examples
---
- name: Configure the iDRAC eventing attributes
dellemc.openmanage.dellemc_configure_idrac_eventing:
idrac_ip: "192.168.0.1"
idrac_user: "user_name"
idrac_password: "user_password"
share_name: "192.168.0.1:/share"
share_password: "share_user"
share_user: "share_password"
share_mnt: "/mnt/share"
destination_number: "2"
destination: "1.1.1.1"
snmp_v3_username: "None"
snmp_trap_state: "Enabled"
email_alert_state: "Disabled"
alert_number: "1"
address: "alert_email@company.com"
custom_message: "Custom Message"
enable_alerts: "Disabled"
authentication: "Enabled"
smtp_ip_address: "192.168.0.1"
smtp_port: "25"
username: "username"
password: "password"
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
error_info
dictionary
|
on HTTP error |
Details of the HTTP Error.
Sample:
{'error': {'@Message.ExtendedInfo': [{'Message': 'Unable to process the request because an error occurred.', 'MessageArgs': [], 'MessageId': 'GEN1234', 'RelatedProperties': [], 'Resolution': 'Retry the operation. If the issue persists, contact your system administrator.', 'Severity': 'Critical'}], 'code': 'Base.1.0.GeneralError', 'message': 'A general error has occurred. See ExtendedInfo for more information.'}}
|
eventing_status
dictionary
|
success |
Configures the iDRAC eventing attributes.
Sample:
{'CompletionTime': '2020-04-02T02:43:28', 'Description': 'Job Instance', 'EndTime': None, 'Id': 'JID_12345123456', 'JobState': 'Completed', 'JobType': 'ImportConfiguration', 'Message': 'Successfully imported and applied Server Configuration Profile.', 'MessageArgs': [], 'MessageId': 'SYS053', 'Name': 'Import Configuration', 'PercentComplete': 100, 'StartTime': 'TIME_NOW', 'Status': 'Success', 'TargetSettingsURI': None, 'retval': True}
|
msg
string
|
always |
Successfully configured the iDRAC eventing settings.
Sample:
Successfully configured the iDRAC eventing settings.
|
Authors
- Felix Stephen (@felixs88)
© 2012–2018 Michael DeHaan
© 2018–2021 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/latest/collections/dellemc/openmanage/dellemc_configure_idrac_eventing_module.html